Αναπνευστήρας Νεογνών NV8 Αναπνευστήρας Νεογνών NV8 Αναπνευστήρας Νεογνών NV8
Αναπνευστήρας Νεογνών NV8

Αναπνευστήρας Νεογνών NV8

Κωδικός: 09974
Ref. Κατασκευαστή: NV8
Τιμή μη διαθέσιμη
print product to pdfΕκτύπωση προϊόντος
  • Περιγραφή Προϊόντος

Περιγραφή Προϊόντος

Blank page

NV8 Neonatal Ventilator
Specially designed for neonates, NV8 provides the most professional and diversified noninvasive nasal ventilation modes with advanced apnea wakeup function and automatic leakage compensation function.
Accurate and safe fresh gas delivered by iFlow Intelligent system
Closed-loop Control System to protect fragile new life
User-friendly operating system with easy clinical practice to facilitate medical staff
Integrated ventilation solutions providing SNIPPV/NIPPV,NCPAP and HFNC modes for safe ventilator weaning.
The world's leading ventilation modes NCPAP (Nasal continuous positive airway pressure)
+ apnea wakeup function.
Exceptional apnea wakeup function
Sleep apnea occurs among 50% to 60% preterm babies.
Abdomen attached respiration sensor configured provides reliable apnea monitoring and wakeup function, effectively lowering the incidence.
Abdomen attached respiration sensor: Neonates conduct abdominal breathing. Attach the sensor to the abdomen, obvious abdomen up and down movements squeeze the sensor and transforms respiratory signals to electric ones for the system to collect and identify.
Apnea wakeup function: When there is no spontaneous breathing signal detected during the preset apnea interval, give out one time inspiratory pressure for apnea wakeup,
or switch to backup ventilation.
NIPPV (Nasal intermittent positive pressure ventilation)
Through increasing the pressure of the upper respiratory tract by intermittently increasing pharyngeal pressure, and through encouraging respiratory movements by intermittent laryngeal expansion, NIPPV can produce higher average airway pressure than CPAP and can increase alveolar filling. This would effectively improve oxygenation and ventilation,
reduce patient’s work of breathing (WOB), and increase functional residual capacity (FRC).

Maximum 15 seconds long inspiratory time, ensuring smooth and spontaneous breathing under bilevel pressure.
SNIPPV (synchronized nasal intermittent positive pressure ventilation) + backup ventilation) Synchronization with breathing: when patient inhales, its abdomen goes up and triggers the sensor to send out inspiratory pressure synchronically, reducing man-machine confrontation and WOB, smoothing the breath.
Abdomen attached respiration sensor: Accurately identify respiratory waveform, synchronically be triggered and precisely monitor respiratory rate (RR).
Backup ventilation: When patient stops breathing for longer than the preset apnea interval, NV8 will automatically switch to backup ventilation and ventilate patient as per preset RR to prevent sleep apnea.
HFNC (High flow nasal cannula) + pressure monitoring function Compared with traditional oxygen therapy instrument, NV8 makes real-time pressure monitoring and waveform display possible, guaranteeing ventilation safety under HFNC mode and preventing
unpredicted consequences due to overpressure.
Comes standard with Fisher & Paykel humidifier, offering warm and fresh gas for neonates
One button for fast oxygen ventilation
Maximum 120 seconds oxygen output with high concentration, one-button operation, quick SpO2 restoration after clinical care, reducing workload.
Manual ventilation
Higher airway pressure feasible based on clinical needs, maximum 15-second continuous ventilation manually.
Quick parameter setting, greatly reducing workload
Direct pressure setting
Traditional CPAP devices with low degree of automation requires manual repetitive airflow adjustment to control pressure. Also, pressure monitoring from a distal end (in the device) fails to truly reflect patients airway pressure.NV8 directly sets the value of pressure for
fully automatic pressure control.
iFlow Intelligent Closed-loop Control System: Intelligently adjusts fresh gas flow and airway pressure in a closed loop. Also, proximal pressure monitoring (under the nose) and real-time
leakage compensation enable stable pressure output.
Quick parameter setting, greatly reducing workload
Direct pressure setting
Traditional CPAP devices with low degree of automation requires manual repetitive airflow adjustment to control pressure. Also, pressure monitoring from a distal end
(in the device) fails to truly reflect patients airway pressure.NV8 directly sets the value of pressure for fully automatic pressure control.
iFlow Intelligent Closed-loop Control System: Intelligently adjusts fresh gas flow and airway pressure in a closed loop. Also, proximal pressure monitoring (under the nose) and real-time
leakage compensation enable stable pressure output. 
Incorporates with Medin company's Medijet pressure generator
Patented technology using Coanda effect,Produces proximal positive airway pressure.
Exhaled air vented out proximally, reducing CO2 residual more effectively and also reducing at most 75% WOB compared with traditional CPAP devices.
Automatic leakage compensation
In case of leakage, iFlow Intelligent Closed-loop Control System will compensate gas in real time to guarantee stable positive airway pressure. Its maximum 25% compensation is incomparable by traditional CPAP devices.
Oxygen concentration one-button auto-calibration avoid incorrect operation due to human error, provide accurate and reliable oxygen concentration data.
Self-check function when start up ensure ventilation safety, reduce medicare providers' waiting time and get ready to use machine
LED touch screen
8”LED-backlit LCD, touch screen; clear and bright from multiple angles, monitoring data
highlighted, intuitive setting design reducing human errors, enabling doctors focusing on
neonates.

ΜΑΘΕΤΕ ΠΡΩΤΟΙ ΓΙΑ