Description:With voice alarm that meets your clinical needs from Basic Life Support (BLS).
print product to pdfPrint product
  • Description

Description

Blank page
Manual defibrillator biphasical Defi Xpress with monitor
Modern, semi-automatic two-phase defibrillator with monitor for professional use.
It has manual and automatic operation, external pacemaker and vital signs monitor.
parameters.

Monitor
Display type: High Resolution & Full Color
Screen size: 8 inches
Scanning Speed: 25mm/sec
Information: Heart Rate . Alarm . on/off . SpO2.
AED
Functions and prompts
Alarm selection and delivered energy limits.
6 languages to choose from
mini SD card for memory upgrade

Defibrillation
Waveform: biphasic (BTE)
Charging time: less than 7 seconds with a new fully charged battery.
Power indicator: The display screen shows both the selected and
The display shows both the energy selected and the energy delivered.
Charging prompt type: Voice and visual messages.
Electrode impedance measurement range: 0-250 ohms.

ECG monitoring
Patient connection: 3 lead ECG cable or 5 lead ECG cable paddles.
Electrode selection: Shown on the display paddles I II III AVR AVL AVF V.
ECG size: 0.25 0.5 1 1.5 2 4 cm/mV Displayed on screen.
Heart rate: 20-300 BPM.
Heart rate alarm: On/Off displayed on screen with option to select
On/Off: on/off display with user selectable option.
Smart alarms: Beeps/voice messages indicate rhythm that
The audio signals and alarms indicate the rate at which it may be beating.

Battery
Type: rechargeable Ni-MH 12V battery.
Operating time: For a new fully charged battery: 60 defibrillator discharges
For a new charge of one new defibrillator, discharge at maximum power or at least 3 hours of continuous ECG monitoring. Additional
Additional parameters will affect operating time with different modes.

SpO2 unit (Options):
Measurement range: 30~100% ±2% between 80%~90% other ±5%
Alarm range: The high limit and low limit are set by the user.
Alarm accuracy: ±10% within the setting values.
Alarm time Accuracy: less than 12 seconds.
Pulse oximeter

NIBP (Options):
Method: automatic oscillation
Mode: manual/automatic
Measure: adult: 10-250mmHg
Ement: pediatric: 10-200mmHg
Rage: neonatal: 10-135mmHg

EtCO2 module (Optional):
CO2 range 0 to 13% (0-98.8
mmHg)
CO2 accuracy <5.0% CO2 (in BTPS) ± 3 mmHg
>5.0% CO2 (in BTPS) < 10% of reading
Respiration rate 3-60 BPM
Measurement accuracy ±1BPM

Pacemaker (Options):
Type: VVI
Pulse type: rectangular, constant current
Pulse range: 0 to 180 mA ± 10% or 5 mA (whichever is greater).
Pacing rate: variable from 30 ppm to 180 ppm ±1,5% (increments or
decreases by a value of 2 ppm)
Multi-function electrode: (MFE) Pads: electrodes
Multi-function defibrillation/pacing electrodes
Pause: Pacing pulse rate is reduced by 4 when activated
Refractory period: NC (VVI demand does not have this specification)
Pulse width: (20+ 1.5 ms)
Output protection: Fully protected and isolated with defibrillator

Printer
Paper: 50mm thermal.
Speed: 12.5mm/sec 25mm/sec 50mm/sec 50mm/sec. Delay of 6 seconds with
user selectable.
Printing method: high resolution thermal print head.
Printing modes: manual or user-configured automatic.
On/Off control: front panel and paddle.
Automatic mode: 9-second recording that starts on alarm activation
or defibrillator charging or defibrillator discharge.

AED function
AED mode: automatic analysis and charging x3 with programmable alerts
automatic energy level selection screen and voice messages.
Shocking rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with
Cardiac ventricular rate >=140bpm and QRS complex wave duration >=140ms.
Charge control.
On the front panel of the device, press the button on the paddle.
Voice and visual commands

Manual operation
Action selection: Select at 2 5 7 10 20 30 50 70 100 150 200 300 360 Joules.
Synchronized mode: Synchronizes the defibrillator pulse with the defibrillator pulse
Synchronizes the pacing of the patient's pulse

Battery
High Capacity Type: Ni-MH 12V volt - MEDITECH
Up to 4 hours of ECG monitoring or 110 full power discharges or 3 hours
combined ECG Spo2 and monitoring
Proper battery care is required to maintain maximum available
capacity.
Low battery indicator:
Flashes the low battery icon on the display and flashes the LED on the
front panel..
Recharge rate: 80% in 7.5 hours. 100% in 9 hours.

Operating conditions/storage conditions
Temperature: 0 to 45°C
Humidity (NC): 15 to 95% RH (30 to 90% with CO2 detector)
Vibration: MIL-STD 810E
Shock / Drop: MIL-STD 810E
Altitude: Up to 4572 M (15000 ft)
Transportation and storage:
Temperature: -30 to 70°C (-20 to 70°C with CO2 sensor)
Humidity: 15 to 95% RH (no condensation)
Atmospheric pressure: 860 to 1060 hPa
Shock/Vibration: ISTA 1A
Enclosure protection:
Solid foreign object: IEC 529 IP2X
Water: IEC 529 IPX4.
All tests conducted in accordance with AAMI DF-2 Defibrillation Standard.

The standard configuration includes:
Five-pole patient cable
AED adult paddles
AED Paddles AED paddles AED adapter
Power supply cable
1 x roll of paper
Cleaning cloth